TITLE:

ES&H Manual

 

DOCUMENT ID:

Installed Monitoring

Out-if-Service

 

 

If an installed ODH monitoring devices is out-of-service perform the following measures:

 

Step 1:         Post a warning at the entrance to the area.  Include appropriate:

·       “Temporary Posting” verbiage, and

·       “Entry Requirements.”

 

Step 2:         Submit a Facilities Management Work Request for repair of the unit.

 

Step 3:         Upon completion of repair, remove the posting.

 

Area ODH Classification

Time Limit

Without Temporary Monitoring

(Restricted Entry)

With Temporary Monitoring

(Unrestricted Entry)

Temporary Posting

Entry Requirements

Temporary Posting

Entry Requirements

ODH 0

No Limit

Not Required

Not Required

Not Required

Not Required

ODH 1

8 days

“KEEP OUT – Potential ODH Area”

ODH Qualified

Class 0, 1, 2, 3

“Temporary

ODH Monitoring in Place”

Temporary Monitoring

+

ODH Qualified

ODH 2/3

28 days

“KEEP OUT – Potential ODH Area”

ODH Qualified

Class 0, 1, 2, 3

“Temporary

ODH Monitoring in Place”

Temporary Monitoring

+

ODH Qualified

Class 0, 1, 2, 3

ODH 4

Immediate Repair

“DANGER - KEEP OUT

Potential ODH Area”

ODH Qualified

Class 0, 1, 2, 3, 4

“DANGER - KEEP OUT Potential ODH Area”

No Entry Allowed

 

 