[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: BCAL time resolution update



Hi Alex,

I assume all the cuts you made are the same. Does anyone have any idea 
what would have changed or is different in the data file to give you a 
better 1/sqrt(E) fit? I had to make some ssignificant cuts on the ADC to 
get a fit like that otherwise it follows 1/E.

-Blake

Alex Dzierba wrote:
> Hi All
>
> David Lawrence created a new data file for me for Run 2334.
> Attached is the time resolution as a function of energy based
> on 0.5*(N-S time difference) for segment 8 after time-walk
> correction.  I don't know what changes were made in the
> new data file - but I now get a good fit to the conventional
> resolution dependence on energy.  Recall the the expected
> contribution to the floor term from beam width should be 32 ps.
>
> Will pursue - have to catch my flight.
>
> Alex
>
> ------------------------------------------------------------------------
>
> ------------------------------------------------------------------------
>
> No virus found in this incoming message.
> Checked by AVG Free Edition. 
> Version: 7.5.516 / Virus Database: 269.20.6/1282 - Release Date: 15/02/2008 7:08 PM
>