fADC stop pointer
Hall D Electronics:
Hi All,
I did a test concerning fADC timing, it is described in:
http://www.jlab.org/Hall-D/software/wiki/index.php/FADC_timing
In short: it turns out that the stop pointer returned by the fADC jumps 
around (~20ns or 4 bins) - I believe this should not be the case. This 
test was performed using the internal clock in the fADC - I will repeat 
this test with the external clock. This behavior is confirmed by Gregg 
Franklin an Diana Parno who use the same fADC with different readout 
software for the Hall-A polarimeter upgrade (they saw a cut-off at the 
end and I saw the rising edge moving -- see description on the website).