[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Gluex doc 1131: response function
Hall D Electronics:
Hi Fernando,
By looking at figure 6 in your document and comparing it with the response
function I measured, I see that I have the same shape but in my cased the
response is three times as long. I checked my input signal again (which
is a step function and is shown in
http://www.jlab.org/Hall-D/software/wiki/index.php/Electronic_chain_simulation
)
The rise time of this step is 12.5-20~ns - I think this can cause a
response function that is too long. This has an implication for how we we
determine the gas-gain and on how we simulate the CDC response.
Would it be easy for you to provide me with an (eg. ascii) file containing
your response function when you inject a step function in the CDC HV-board
(a sample/ns) in your simulation? - guess you have to add the HV
board-circuit. Also, is (Gerard's) shaper included in the circuit in
figure 4 or is this just the pre-amp?
Thanks a lot!
Cheers,
Yves
/--------------------------------
/ Yves Van Haarlem
_--~~--_ /
/~/_| |_\~\ / Carnegie Mellon University
|____________| / Department of Physics
|[][][][][][]|:= / Wean Hall room 8404
__| __ |__ \ Pittsburgh, PA 15213
| ||. | == | | \ USA
(| ||__| == | |) \
| |[] [] == | | \ Tel.: +1 412 268-6949
| |____________| | \ +1 412 641-9252
/__\ /__\ \ Fax.: +1 412 681-0648
~~ ~~ \-----------------------------------