Radcon calculations from Pavel
From Pavel:
The table of up to date results follows:
target wall roof lead dumpline boundary_dose_rate
none 10cm 10cm yes yes 0.33+/-0.11 urem/h
H30cm 10cm 10cm yes yes 1.60+/-0.17 urem/h
H30cm 10cm 10cm no yes 1.54+/-0.16 urem/h
H30cm 10cm 10cm no no 1.50+/-0.20 urem/h
H30cm 1cm 1cm no no 3.23+/-0.36 urem/h
H30cm 10cm 5cm no no 1.96+/-0.15 urem/h