[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: notes from today's meeting



Tim,
It comes close.  To know whether it makes spec or not, we need to know what limits it places on the cable run, and whether we can respect those limits within the tagger hall or not.  Our spec also states that the inside diameter of the beam pipe through the quad is 30mm ± 2mm.  What are the standard pipe sizes that fit through this bore?  Can we get one with an inner diameter >= 28 mm?
Richard Jones

Tim Whitlatch wrote:
4790E8BD.8010004@jlab.org"> Thanks Richard,

Below is the spec for a standard JLAB QP magnet. At 19amps, it can just make the spec for Hall D.

Compare to QP

















Bore 3.81 cm 1.5 in





Length 30.48 cm


19 amps ability depends on cable run
Max B'l 75 kG Design at 18 amps
82 kG Design at 19 amps

Would this work?


S/MIME Cryptographic Signature