Hello all,
As we had discussed during yesterdays meeting, I have posted some
drawings showing the critical dimensions and interfaces for the magnet,
hodoscope, microscope and vacuum chamber. I know some of these do not
match what is currently being used in the software. I took a stab at the
magnet dimensions with the increased step in the poles for the vacuum
chamber walls. I have posted the drawings in order to get feedback and
consensus on the required numbers. Please review them and add return
comments to the email list. In order to have a reasonable set of
consistent drawings for the Tagger review, these need to be nailed down
within a week. If I missed anything or misrepresented anything, please
let me know. The drawings are on the wiki at;
http://www.jlab.org/Hall-D/software/wiki/index.php/Tagged_Beam_Group_Engineering_Drawings
The last 2 links under the Tagging spectrometer with the Sept. 26, 2008
date.
Cheers,
Tim