[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Tagger interfaces



Hello Tim,

I looked on the drawing:

-The positions of a dipole magnet and
fixed array counters (the first and last counters) seem
to be correct (+- few mm).

-the exit flange (end plate) of the vacuum chamber has to
be modified a little bit; as we have discusses the plate 
should go perpendicular to the electron beam (I will check with
James). The electron beam going to the dump seems to be at the
right position from the egde of the vacuum chamber.

-the quadrupole magnet has not been moved
  (in the MC it's placed downstream the beam) (?)

Cheers,
       Sascha





On Tue, 24 Feb 2009, Tim Whitlatch wrote:

> Hello all,
>
> The updated (Feb 23, 2009) tagger interface drawings are now posted on the 
> wiki @
>
> http://www.jlab.org/Hall-D/software/wiki/index.php/Tagged_Beam_Group_Engineering_Drawings
>
> sheets 1 and 2
>
> Please have a good look at these. Pay close attention to the quad location, 
> distance to scintillators and downstream window. Please let me know if these 
> meet the current requirements. We will then release this version so the 
> machine group can use these positions.
>
> Cheers,
>
>      Tim
>
>