Hi,
	Yes this is fine for my schedule as well. Please send dialing info when 
you have it.
	Yves, also note I certainly don't claim now (nor back then) to have 
exhaustively surveyed the possible connectors nor inquired for 
availability. For instance, my suggested part number today was simply an 
attempt to address the voltage rating issue, it is not necessarily the 
optimal choice. It is also true, this whole style of connector, 
developed probably in the early 50's, is falling out of favor, so may be 
hard to obtain. It will be good if the CDC group can make a thorough 
study of the options, including for instance if the 1800VAC connectors 
are just not an option, in which case all is not lost but more work may 
be needed to certify the safety of the design.
	I believe that the connector characteristics we need are:

	- 24 signal pins, 2+ ground pins, as many unused pins as may be.
	- hi-pot withstanding (by our own test) to at least 150% of CDC bias 
voltage, including feasible pcb routing
	- approvability by the safety review committee
	- gas tight, noncontaminating (probably means you build up the seal 
with epoxy or something)
	- support of pcb board directly by connector would be nice
	- small enough (not a serious constraint given the footprint of 24 
straws on the endplate)
	- anything else??

	Thanks,

	Gerard

Fernando J. Barbosa wrote:
> Hi Yves,
> 
> It works for me. I am also CCing Tim and Slava in case they want to join.
> 
> Regards,
> Fernando
> 
> 
> 
> 
> Yves Van Haarlem wrote:
>> Hi All,
>>
>> About the phone conference. Curtis is at JLab next week and he can
>> meet all Wednesday, Gerard and me could phone in. So what about having
>> a meeting next week Wednesday at 1pm (first iteration)?