Re: CDC Electronics Assembly



Hi Gerard,

Indeed that thickness may be too much for the reasons you mention. As 
you know, attaching the shields is a labor intensive procedure and there 
are not many ways to improve on that. I like your suggestion of just 
bending that thin piece for connection to the pins 13 and the holes can 
just be stamped.

Thanks,
Fernando




Gerard Visser wrote:
> Hi Fernando,
>     Do you really want the tie plate to be 1/8 inch thick? Such a 
> massive part, I suspect, will lead to melting and distortion of the 
> polyethylene insulation of the RG-174 cables when it is soldered. I 
> think it will be much better to have ~0.004 inch copper or brass (for 
> easier machining).
>
>     Gerard
>
> p.s. If you follow this suggestion you can probably also just bend the 
> end down to connect to the pins 13, rather than soldering an extra 
> wire between the tie plate and the pins 13.
>
> Fernando J. Barbosa wrote:
>> Hello everyone,
>>
>> I have updated the drawing on the suggested CDC electronics assembly
>> procedures.
>>
>> Regards,
>> Fernando