CDC configuration
Hi All,
I had some information exchange with Slava this morning. And I realized many
different parameters and issues regarding the end-plate are not familiar
to everybody.
like the following:
1) from mechanical tolerances there need to be a "gap" between tubes
in a given layer of about 0.1mm to 0.15mm depending on the tolerances
of the tube itself and its parts at the end.
this is true not just at the end-plate but also at the center of
the CDC for axial and stereo layers.
Distances of 20 micro meters between straws is not realistic
considering that there are no
numbers available for tolerances of the tube diameter, wall
thickness, glue joints, etc.
2) at the same level one could rather change the number of tubes in a
given layer then changing
its radius and play with the gap between straws (-> point 1)
3) there needs to be sufficient spacing after the last straw for the gas
cover sheet and
the support rods (about 1.9") as well as the suspension mechanism.
4) since the straws have to be custom made one could think of make them
a few micro meters
smaller in diameter to fit 28 layers in the allocated space.
5) the holes into the end plate have to be specified with position and
angle such that a CNC machine
can be programmed accordingly.
6) ...other points ??
we really need a meeting to discuss this with all parties involved to
settle all the issues once and for all.
If we could meet still this week would be great. How about
Thursday late afternoon say 4:00pm ?
or Friday morning say 9:30am ?
cheers,
Beni
--
***********************************************************