[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Lead glass blocks
My two cents...
Tim,
lead tungstanate is a very different thing. It makes a scintillating
crystal (not glass), which light yield
depends on temperature significantly. In contrast, a lead glass detector
produces only the Cherenkov light, which does not depend on temperature.
Eugene
>Hi Matt,
>
>I spoke with Dave Kashy about the Hall B primex lead glass calorimeter.
>They used lead-tungsten glass and it had to be cooled in order to
>perform properly. Do we require any cooling for ours taking into
>consideration the type of material we will use for the rad hard inner
>layers?
>
>Thanks,
>
> Tim
>
>