[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

More on radiation shielding



Hi Elliott,

40 cm thick, 5m high retainer wall makes the boundary dose rate 1.8+/-0.2
urem/h, and
max. dose outside the Hall 30-50 urem/h. Counting house will have 5-10 urem/h.
All this
with roof and upper wall 10 cm thick (all concrete). No lead and no beam
dumpline.
I think I've completed what we decided to do for now. Over to you...

Regards,
Pavel