[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Table of Radcon Configuration Studies Jul 18
Elton Smith
Jefferson Lab
elton@jlab.org
(757) 269-7625
---------- Forwarded message ----------
Date: Tue, 18 Jul 2000 15:55:44 -0400
From: Pavel Degtiarenko <pavel@jlab.org>
To: Elliott Wolin <wolin@jlab.org>, Elton Smith <elton@jlab.org>
Cc: Bob May <may@jlab.org>
Subject: Re: Last results
Hi Elliott,
The table of up to date results follows:
target wall roof lead dumpline boundary_dose_rate
none 10cm 10cm yes yes 0.33+/-0.11 urem/h
H30cm 10cm 10cm yes yes 1.60+/-0.17 urem/h
H30cm 10cm 10cm no yes 1.54+/-0.16 urem/h
H30cm 10cm 10cm no no 1.50+/-0.20 urem/h
H30cm 1cm 1cm no no 3.23+/-0.36 urem/h
H30cm 10cm 5cm no no 1.96+/-0.15 urem/h
Next I am going to play with the thickness of the retainer wall and its height to
try to reduce the dose rates in the vicinity of the hall below 50 urem/h.
I've got another question: is the 30 cm liq.H2 target the heaviest target that you
plan to use in the Hall D? How about liq.D2 - would it be shorter? Does anybody
envisage using of a nuclear target - and at what thickness?
Regards,