[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Primex beam requirement
Hi Richard,
They are very similar, thanks. What is the collimater radius
for your simulation? It looks like R = 1.7 mm, is that right?
Ashot
.............................................................
Ashot Gasparian Phone:(336)285-2112 (NC A&T)
Associate Professor
Physics Department (757)-269-7914 JLab
NC A&T State University Fax:(757)-269-6273 JLab
Greensboro, NC 27411 email: gasparan@jlab.org
.............................................................
On Sat, 6 Dec 2008, Richard Jones wrote:
> Ashot, Liping:
>
> Those requirements are within the capabilities of the tagger and collimation system that we have in our current
> design for the Hall D photon beam. I have carried out a more complete simulation of the photon beam spot at the
> position of the gluex target than what Liping did. You can compare the two plots (x and y projections of the
> beam spot profile) below with Liping's profiles. They look similar to me.
>
> http://zeus.phys.uconn.edu/halld/primex/beam-12-2008/xtarg_beam.gif
> http://zeus.phys.uconn.edu/halld/primex/beam-12-2008/ytarg_beam.gif
>
> -Richard J.
>
>
> Gan, Liping wrote:
> Dear Richard,
>
> According our discussion at the meeting, here is updated beam requirement for PrimEx experiment.
>
> Best regards,
>
> Liping
>
>
>
> ____________________________________________________________________________________________________________
>
> [IMAGE]
>
>
>
>