Re: Primex beam requirement



Title: reminder: photon beam working group meeting 12/4 @ 9:30
Ashot, Liping:

Those requirements are within the capabilities of the tagger and collimation system that we have in our current design for the Hall D photon beam.  I have carried out a more complete simulation of the photon beam spot at the position of the gluex target than what Liping did.  You can compare the two plots (x and y projections of the beam spot profile) below with Liping's profiles.  They look similar to me.

http://zeus.phys.uconn.edu/halld/primex/beam-12-2008/xtarg_beam.gif
http://zeus.phys.uconn.edu/halld/primex/beam-12-2008/ytarg_beam.gif

-Richard J.


Gan, Liping wrote:
621A1D0B68C2594C80895862954FBB6B0E752A6A@UNCWMAILVS1.dcs.uncw.edu">
Dear Richard,
 
According our discussion at the meeting, here is updated beam requirement for PrimEx experiment.
 
Best regards,
 
Liping