[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: A few questions (fwd)




HI Elke,

One note on the rates which we should add, is that the 600 KHz in the FDC
downstream chambers corresponds to 0.6 deg (this assumes the same dead
region all through the drift chambers. The rate for 1 degree openning is
closer to 150 KHz maximum or a 5% aperture.

This might be a number whis is useful to quote in answering the first
question.

Cheers, Elton.




Elton Smith
Jefferson Lab MS 12H5
12000 Jefferson Ave
Suite # 16
Newport News, VA 23606
elton@jlab.org
(757) 269-7625

On Wed, 7 Mar 2007, Elke-Caroline Aschenauer wrote:

>
> Dear all,
>
> we have to find answers to this questions I suggest we discuss them in the
> coffee break.
> Dan I print you document on the costing of the fdc to give it to them,
> that should answer definetely all on it for the fdc, Curtis can we give
> them what you gave in former times and lately to elton to be included in
> the costbook.
>
> For the rest I guess it should be not very difficult to find answers.
>
> Regards
> elke
>
>
>
>  ( `,_' )+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=
>   )    `\                                                  -
>  /    '. |                                                  +
>  |       `,              Elke-Caroline Aschenauer            =
>   \,_  `-/                                                    -
>   ,&&&&&V         Jefferson Lab                                +
>  ,&&&&&&&&:       HALL-D 12C / F381       121-A Atlantic Avenue =
> ,&&&&&&&&&&;      Mailstop: 12H5          Hampton, VA 23664      -
> |  |&&&&&&&;\     12000 Jefferson Ave                             +
> |  |       :_) _  Newport News, VA 23606  Tel.:  001-757-224-1216  =
> |  |       ;--' | Mail:  elke@jlab.org    Mobil: 001-757-256-5224   -
> '--'   `-.--.   |                                                    +
>    \_    |  |---' Tel.:  001-757-269-5352                             =
>      `-._\__/     Fax.:  001-757-269-6248                              -
>             +=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+
>
> ---------- Forwarded message ----------
> Date: Wed, 07 Mar 2007 08:02:21 -0600
> From: David Christian <dcc@fnal.gov>
> To: elke@jlab.org
> Cc: David Christian <dcc@fnal.gov>, brooksw@jlab.org, whitlock@jlab.org
> Subject: A few questions
>
> Dear Elke,
>
> After yesterday's session, we have a few questions the answers to which
> would help us as we consider what to write in a report.  I would
> appreciate it if you could respond today:
>
> 1) What calculation/simulation has been done of the background processes
> that will dominate the rate in the chambers?
>
> 2) It appears that the minimum allowable straw radius is set by a
> maximum allowable rate that is calculated assuming that a dE/dx
> measurement needs to be made in these straws.  Is this correct?  If not,
> how was the maximum allowable rate estimated?
>
> 3) Do you have supporting material available for the cost estimates?
>
> 4) Since the configuration of magnet steel is being changed, we are
> somewhat concerned with the fact that you do not plan to map the field.
>   What drove this decision?
>
> Sincerely,
> David Christian
>
>
>