[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Note on induced currents and forces during quench



Thanks Elton,

The bottom line;

We electrically break the ground plane in the FDC
We electrically break the BCAL wedge circle
We support the upstream CDC endplate to prevent axial movement during a 
quench.

Thanks,

       Tim

Elton Smith wrote:
> HI all,
>
> I have posted GlueX-doc-973 with estimates for the currents and forces
> induced in the bcal, fdcs and cdcs during a quench. They are
> back-of-the-envelope estimates, but show that precautions are needed to
> address the consequences during our design.
>
> Comments, suggestions (and corrections) are welcome.
>
> Cheers, Elton.
>
> Elton Smith
> Jefferson Lab MS 12H5
> 12000 Jefferson Ave
> Suite # 16
> Newport News, VA 23606
> elton@jlab.org
> (757) 269-7625
> (757) 269-6331 fax
>