It looks good. However, I suggest you add another ground cable (black?)
and perhaps connect both ground cables to a single crimp eyelet. For
reliability, I would also connect another HV shield wire (red?). Maybe
these are already there but I cannot see from the picture.
A small detail. Do you plan to apply any conformal coating (acrylic)
over the the shield solder joints? This is just to prevent any shield
wires from contacting any other object and to keep them secure. Please
avoid any silicone based wires or products that go on the gas volume.
Regards,
Fernando
Yves Van Haarlem wrote:
> Hi All,
>
> On
>
> http://www.jlab.org/Hall-D/software/wiki/index.php/Image:Edacconn.jpg
>
> you can see how Gary prepared the connector and the cables in order to
> be inserted and hooked up with the wires. We used RG-188A/U cables
> which have teflon and are much more heat resistant (good for
> soldering). The whole assambly is pretty stiff and rigid. We'll have
> to see hpw difficult it is to connect it to the wires.
>
> Cheers,
> Yves
>
> /--------------------------------
> / Yves Van Haarlem
> _--~~--_ /
> /~/_| |_\~\ / Carnegie Mellon University
> |____________| / Department of Physics
> |[][][][][][]|:= / Wean Hall room 8404
> __| __ |__ \ Pittsburgh, PA 15213
> | ||. | == | | \ USA
> (| ||__| == | |) \
> | |[] [] == | | \ Tel.: +1 412 268-6949
> | |____________| | \ +1 412 641-9252
> /__\ /__\ \ Fax.: +1 412 681-0648
> ~~ ~~ \-----------------------------------
begin:vcard
fn:Fernando J. Barbosa
n:Barbosa;Fernando J.
org:Jefferson Lab
adr:Suite #10, 12B3;;12000 Jefferson Ave.;Newport News;VA;23606;USA
tel;work:757-269-7433
version:2.1
end:vcard