[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Collimator layout



Hi Richard et al,

Thank you for the feedback. We will look this over and correct the model and produce new top and side views. We will also add the materials.

Cheers,

       Tim

Elke-Caroline Aschenauer wrote:
On Wed, 21 May 2008, Elton Smith wrote:

Actually I think we need a side and a top view to have all dimensions
available easily. As we want to check this drawin than vs the Monte Carlo.

cheers elke


  
Date: Wed, 21 May 2008 10:16:11 -0400 (EDT)
From: Elton Smith <elton@jlab.org>
To: Richard Jones <richard.t.jones@uconn.edu>
Cc: Tim Whitlatch <whitey@jlab.org>,
     Hall D beam working group <halld-tagger@jlab.org>
Subject: Re: Collimator layout


HI Tim,

On the drawing it would also be very useful to show the materials in each
of the blocks. (Fe, concrete, Pb, etc).

Thanks, Elton.




Elton Smith
Jefferson Lab MS 12H5
12000 Jefferson Ave
Suite # 16
Newport News, VA 23606
elton@jlab.org
(757) 269-7625
(757) 269-6331 fax

On Wed, 21 May 2008, Richard Jones wrote:

    
Tim,

Here are some comments on the collimator cave layout views you sent me.
 1. The vacuum pipe that carries the photon beam from the tagger hall to the
    collimator cave is shown as 5cm in diameter.  The civil plans show a stainless
    steel pipe 10 inches in diameter connecting the two halls.  The simplest plan
    would simply be to evacuate the entire 10 inch pipe (only rough vacuum is
    required) in which case the pipe that enters the cave area should have a diameter
    of 25.4cm.
 2. The primary collimator should be 30cm long.  In the drawing it looks like only
    15cm.
 3. The pole gap in the first sweep magnet is nominally 2cm.  This is not shown, and
    is subject to change as we refine the specs on the sweeps.
 4. The hole through the 200cm iron shielding block is shown at 1cm dimensions.  It
    should be a 2cm x 2cm square hole.
 5. The hole through the 100cm x 200cm x 200cm concrete shielding block is shown at
    1cm dimensions.  It should be a 2cm x 2cm square hole.
 6. The secondary collimator is shown as 25cm long, or so.  The length in my geometry
    is 50cm, with a circular bore hole diameter of 5mm.
 7. The inner dimensions of the cave area in my description were 270cm high  x  450cm
    wide.  The lead wall separating the cave from the main hall area was designed
    with dimensions 470cm x 270cm to completely cover the opening in the vertical
    direction (270cm) and to go 10cm past the left and right inner wall dimensions.
    This could be accomplished by a notch in the side walls at the entrance to the
    cave.
Richard Jones


 1. Tim Whitlatch wrote:
      Hi Richard,

      Slava has dimensioned the collimator layout as supplied in Igor's Autocad
      file. There are many dimensions for the shielding sizes as well as the
      beamline locations. Please look this over and let me know if this is what
      is needed as far as locations and size. There is a top and side view .pdf
      attached.

      Thanks,

            Tim





      
    
 ( `,_' )+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=
  )    `\                                                  -
 /    '. |                                                  +
 |       `,              Elke-Caroline Aschenauer            =
  \,_  `-/                                                    -
  ,&&&&&V         Jefferson Lab                                +
 ,&&&&&&&&:       HALL-D 12C / F381       121-A Atlantic Avenue =
,&&&&&&&&&&;      Suite 8                 Hampton, VA 23664      -
|  |&&&&&&&;\     12000 Jefferson Ave                             +
|  |       :_) _  Newport News, VA 23606  Tel.:  001-757-224-1216  =
|  |       ;--' | Mail:  elke@jlab.org    Mobil: 001-757-256-5224   -
'--'   `-.--.   |                                                    +
   \_    |  |---' Tel.:  001-757-269-5352                             =
     `-._\__/     Fax.:  001-757-269-6331                              -
            +=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+=-+

  
begin:vcard
fn:Timothy Whitlatch, PE
n:Whitlatch;Timothy
tel;work:757-269-5087
tel;fax:757-269-5279
version:2.1
end:vcard