[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
FYI
Hi All,
here some additional information for tomorrows meeting.
1) in the NIM article A303 (1991) 277-284 the straws for E735 at Fermilab
the following straws were manufactured by Stone Industrial Division,
College Park 20704, MD, USA
75 micro meter mylar
75 micro meter paper
18 micro meter aluminum
2) attached is a rough outline of how one could avoid the cable
connection between the crimp pins
and the plug for the HV boards. The idea is based on using several
PCB boards that fit over
crimp pins supported by small pillars. The connection between the
crimp pin the the traces in
the board would be done using conducting rubber. Pins sticking out
of the PCB board would
provide the interface to the connector the plugs in through the hole
in the plastic sealing plate.
Fernando is testing the feasibility of the PCB for laying traces
and pins for the connection in
terms of the space available.
cheers,
Beni
--
***********************************************************
Benedikt Zihlmann
TJNAF
HallD 12C/ F350
Suite 8
12000 Jefferson Av.
Newport News VA, 23606
tel: 757 269 5310
fax: 757 269 6331 zihlmann@jlab.org
***********************************************************
CDC-pcb.pdf